• Solar Controller Systemsolar Energy System 30kwsolar Controller System Water Heater Pressur
  • Solar Controller Systemsolar Energy System 30kwsolar Controller System Water Heater Pressur
  • Solar Controller Systemsolar Energy System 30kwsolar Controller System Water Heater Pressur
  • Solar Controller Systemsolar Energy System 30kwsolar Controller System Water Heater Pressur
  • Solar Controller Systemsolar Energy System 30kwsolar Controller System Water Heater Pressur
  • Solar Controller Systemsolar Energy System 30kwsolar Controller System Water Heater Pressur

Solar Controller Systemsolar Energy System 30kwsolar Controller System Water Heater Pressur

Condition: New
Certification: ISO, CB, CE
Application: Home, Industrial, Commercial
Specification: Normal, CE, RoHS, ISO 9001
Working Time: 6-8hours
Waterproof Degree: IP67
Samples:
US$ 2200/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2008

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory

Basic Info.

Model NO.
SMSH-30KW
Grid Voltage
3/N/P, 220/380V,230/400V
Connector
Mc4
Solar Panel Rack
1 Set
Roof Required Areas
8-10 Sq.Meters Per 1kw
Working Temperature(ºC)
-30 - +60
Charge Method
Utility Grid or Solar Panel
Solar Power Generator Installation
Easy Install with Manuals
Solar Power Generator Protection
Overloads, Low Voltage and Under Voltage (Alarm)
Protection
Overloads, Overcharge, Short Circuit, Polarity Rev
Allowable Max Loads Power
100W~1500W
Connect
Connection Drawing Provided
Delivery Period
7-15days After Receive Payment
PV Array Combiner
IP65
Transport Package
Carton
Trademark
SunMaster
Origin
Zhejiang, China
HS Code
8502390000
Production Capacity
50000pieces/Year

Product Description

Solar Controller Systemsolar Energy System 30kwsolar Controller System Water Heater Pressur
Connecting Diagram


Solar Controller Systemsolar Energy System 30kwsolar Controller System Water Heater Pressur

Configuration List


Solar Controller Systemsolar Energy System 30kwsolar Controller System Water Heater Pressur

Item Certification Description Q'ty Warranty
Solar panel TUV / IEC / EC Mono or Poly,A grade cell,high efficiency 100 pcs 20 years
Inverter CGC / CQC / VDE MPPT tracking/ 220VAC
15KW/ SM-SH15KW
2 set 5 years
Distribution box
(Optional)
CE Lighting Protection. Air switch,Fusegear, knife switch 1 set 5 years
Mounting system CE Slant roof bracket/ Cement Ground bracket/ Soil ground bracket 1set 10 years
PV cable TUV/ UL DC port PV1-F 1*8mm2 400m 10 years
AC port YJV-3*16mm2 50m 10 years


Solar Controller Systemsolar Energy System 30kwsolar Controller System Water Heater Pressur

Solar Panel


Solar Controller Systemsolar Energy System 30kwsolar Controller System Water Heater Pressur

Type MONO POLY
Power class 280W 335W 270W 320W
Open Circuit Voltage (Voc) 43 44 43.0V 43.8
Short Circuit Voltage (Isc) 8.35 9.92 8.23 9.42
Max power Voltage (Vmp) 36 36 36 36.5
Max Power Current (Imp) 7.78 9.3 7.5 8.76
Efficiency ≥17.1% ≥17.2% ≥16.5% ≥16.4%
Dimension (mm) 1650x991x35 1960x991x35 1650x991x35 1960x991x35
Weight (kg) 18±5% 22.5±5% 18±5% 22.5±5%
 
Solar Inverter


Solar Controller Systemsolar Energy System 30kwsolar Controller System Water Heater Pressur

Model parameter GW10kW-MS
Dimension (W*H*D) 516*650*203mm
Weight(kg) 39
Mounting Wall bracket
Ambient temperature range -25~+60ºC(>45ºC deloading)
Relative humidity 0~95%
Max operating altitude 4000m (>3000m derating)
Protection degree IP65
Topology Transformerless
Night power consumption (W) <1
Cooiong method Natural convection
Noise emision (dB) <25
Display LCD
Warranty (Year) 5/10/15/20/25 (Optional) Years
 
PV Combiner Box
Solar Controller Systemsolar Energy System 30kwsolar Controller System Water Heater Pressur
Components Parameter Function
Circuit breaker (Air switch) 100A When the current of the protected,circuit exceeds the specified value,the circuit breaker will automatically break off to protect the whole circuit.
Fusegear 100A When the current of the protected circuit exceeds the specified value,fusegear will break off automatically
Surge protective device (SPD) UC:420V lmax:20KA
In: 10KAUp1.8KV
Photovoltaic lightning protection device
One phase self dual over voltage protection device Working range 220V,50Hz,
over voltage protection
Uvo=270V±5V
Under voltage protection
Uoe= 170±5V
When the circuit voltage is highet or lower, it will shut down automatically.when the voltage reaches standard level, it will recover automatically.
Knife switch / automatic/ by hand


Solar Controller Systemsolar Energy System 30kwsolar Controller System Water Heater Pressur

Conductor
Tinned Fine Re Copper Strand, according to VDE0295/IEC60228. Class 5
Insulation
Polyolefin Copolymer electron-beam coss-linked
Sheath Jacket
Polyolefin Copolymer electron-beam coss-linked
Nominal Voltage
Uo/U=600V/1000VAC, 1000V/1800VDC
Test  Voltage
6500V, 50Hz, 5Min
Temperature Rating
-40°C-125°C ,More than 25 Years  (TUV)
Fire Performance
IEC 60332-1
Smoke Emission
IEC61034, EN 50286-2
Low Fire Load
DIN 51 900
Certification
TUV 2PFG 1169/08 2007 PV1--F
  
Mounging System


Solar Controller Systemsolar Energy System 30kwsolar Controller System Water Heater Pressur

The wind capacity of such mounting system can reach (40m/s, 32.5kg/ square meters, level 13), snow load capacity can reach 70kg/ square eters

The whole system has strong safety performance.

Can be customized based on customer's cactual situation

The mounting system can be desingned with best solution based on slope roof, flat ground and soil ground

 

Solar Controller Systemsolar Energy System 30kwsolar Controller System Water Heater Pressur







 

 

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2008

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory
Number of Employees
52
Year of Establishment
2010-11-11